Convenient access from more than one train stations and railways Seismic isolation structured purpose-built data center which stands earthquake of Japanese scale intensity level 7 (the level of Great Eastern Japan Earthquake in 2011) Achieving PUE 1.3, the top level PUE among all data centers in Japan by adopting high-efficient water-cooled air conditioner, outdoor air cooling system, and end wall injection air conditioning First NTT Com data center in Japan to have stable power supply from two different power substations. Directly connected to robust cable tunnel preventing disaster risks. Excellent connectivity with NTT Com's network services and cloud services.
Located at Osaka Metropolitan Area, diverse routes are available. Easy access from central Osaka on foot even in emergency situation. 7 minutes from the nearest station 20 minutes by train from Shin-Osaka station 1 hour from Kansai International Airport The site is located at 6 km from Osaka Bay and 3 km from the nearest river to prevent the water risks, and the data center could be in operation even in the unexpecting case
Osaka 5 Data Center can reduce seismic shocks to one-fifth and it can also suppress vertical shocks to prevent bad effects on customers' equipment, facilities and building. Communication circuits are connected directly to secure earth-quake-proof cable tunnnels. and to ensure reliability, Osaka 5 Data Center recieves power from two substations with redundant cable routes.
Building Self-designed, purpose-built data center building Steel construction and Seismic isolation, 11-stories Loading capacity of slab floor: 1500 kg/sqm
Power receiving: Dual paths from two substations UPS : N+1 redundant configuration Generator : N+1 redundant configuration Power Provision : Max. 15.0 kW Osaka 5 Data Center achieved highest level of power usage effectiveness, for example by adopting water-cooled air conditioner with outdoor air cooling system, rotary UPS which minimizes power loss and advanced air flow management system.
Air Conditioning Efficient cooling system for high density ICT equipment The fist case deploment of the end wall injection air conditioning for NTT Com's data center in Japan. Water cooling system with N+1 redundant configuration
Fire Protection Gas fire suppression system to protect ICT equipment Early warning smoke detection system, Smoke detectors N2 gas fire suppression system for server rooms
Connectivity Directly connected to secure earth-quake-proof cable tunnel Multiple carriers Proximity to NTT Com's network backbone, Arcstar Universal One, connectivity with NTT Com's other global data centers and cloud services seamlessly
Standard Rack W: 600 mm x D: 1100 mm x H: 46U
Green Performance Top class green performance Efficient water cooling system for high density ICT equipment Indirect free cooling system Hot aisle containment PUE 1.3 ( designed value )
Others Rental office-BCP office is available for customers' multiple-use. Customers are also able to use standby power supply and connectivity service between server room and the BCP office Freight elevator Staging room ISO 27001:2005 ISO22301 PrivacyMark(JIS Q 15001)